TRATAMENTO PARA DESENTUPIMENTO DE GOTEJADORES CONVENCIONAIS
DOI:
https://doi.org/10.15809/irriga.2008v13n2p235-248Abstract
TRATAMENTO PARA DESENTUPIMENTO DE GOTEJADORES CONVENCIONAIS
Marconi Batista Teixeira; Ralini Ferreira de Melo; Rubens Duarte Coelho; Osvaldo Rettore Neto; Pablo Atahualpa de Aguiar Ribeiro
Departamento de Engenharia Rural, Escola Superior de Agricultura Luiz de Queiroz, Universidade de São Paulo, Piracicaba, SP, marconi@esalq.usp.br
1 RESUMO
Este trabalho teve como objetivo verificar a recuperação de emissores convencionais que apresentavam, em campo, problemas de entupimento causados por problemas biológico ou químico. O experimento foi realizado em uma Bancadade ensaios instalada no Laboratório de Irrigação do DER – ESALQ – USP, utilizando-se os seguintes tratamentos químicos da água para recuperação dos emissores: a) 10 mg L-1 de cloro livre; b) 50 mg L-1 de cloro livre; e c) ácido nítrico a pH 2,0. A fonte de cloro utilizada foi hipoclorito de sódio (10%), sendo que o pH foi mantido na faixa de 5,5 a 6,0 para maior ação do ácido hipocloroso. A aplicação das dosagens foi feita durante 2 horas, deixando as linhas gotejadoras descansarem expostas à ação dos tratamentos por 24 horas, quando, então, realizava-se a leitura de vazão. O delineamento experimental adotado foi o DIC em esquema fatorial 5x3, sendo utilizados os testes “F” para análise de variância e Tuckey a 5% de significância para comparação de médias. O tratamento com 50 mg L -1 de cloro livre foi o mais eficiente estatisticamente a 5% de significância pelo teste de Tukey para recuperação da vazão dos gotejadores a valores próximos da vazão nominal de catálogo.
UNITERMOS: irrigação localizada, tratamento químico, uniformidade de distribuição de água.
TEIXEIRA, M. B.; MELO, R. F. de; COELHO, R. D.; RETTORE NETO, O.; RIBEIRO, P. A. de A. TREATMENT FOR CLOGGED EMITTERS
2 ABSTRACT
This work aimed to verify the recovery of conventional emitters that presented blockage problems in the field caused by biological or chemical problems. The experiment was performed in a trial counter installed in the Irrigation Laboratory at ESALQ-USP, using the following chemical water treatments for clogged emitters: a) 10 mg Lˉ¹ of free chlorine,
b) 50 mgLˉ¹ of free chlorine, and c) nitric acid at 2.0 pH. The used chlorine source was sodium hypochlorite (10%) and pH was kept from 5.5 to 6.0. The application was done for 2 hours, then the line emitters rested and exposed to the action of the treatments for 24 hours, when then the flow reading was made. The adopted experimental outline was DIC in a 5x3 factorial scheme, using Tests “F” for variance analysis and Tukey’s at 5% to compare averages. The treatment to recover emitter discharge to its original value was statistically more efficient according to Tukey’s test at 5%, when 50 mgLˉ¹ of free chlorine was applied.
KEY WORDS: trickle irrigation, chemical treatment, uniformity of dripper discharge
Downloads
Published
How to Cite
Issue
Section
License
This magazine provides public access to all its content, following the principle that free access to research generates greater global knowledge exchange. Such access is associated with a growing reading and citation of an author's work. The copyright of articles published in Revista Irriga is the property of the authors, with first publication rights for the journal. Because they appear in this publicly accessible magazine, articles are free to use, for their own purposes, for educational and non-commercial purposes. Further details can be obtained at http://creativecommons.org/licenses/by-nc-nd/4.0