COEFICIENTE DE DESCARGA DE EMISSORES DE PIVÔ CENTRAL
DOI:
https://doi.org/10.15809/irriga.2007v12n1p123-134Abstract
COEFICIENTE DE DESCARGA DE EMISSORES DE PIVÔ CENTRAL
Marconi Batista Teixeira; Ralini Ferreira de Melo; Rubens Duarte Coelho
Departamento de Engenharia Rural, Escola Superior de Agricultura Luiz de Queiroz, Universidade de São Paulo, Piracicaba, SP, marconi@esalq.usp.br
1 RESUMO
Com objetivo de avaliar o coeficiente de descarga para diferentes diâmetros de bocais de aspersores fixos para pivô central, analisou-se 35 bocais de diferentes diâmetros com três repetições, totalizando 105 bocais ensaiados. Para a medição da pressão e vazão, foram utilizados, respectivamente, um manômetro digital e um medidor magnético indutivo de vazão. Foi utilizada água tratada com temperatura ambiente 25oC. Os resultados mostraram que para os menores diâmetros de bocais (diâmetro nominal variando de 2,0 até5,4 mm) o coeficiente de descarga apresentou alguns valores superiores a 1,0; mostrando que com o aumento da pressão ocorre vazamento entre as partes que compõem o bocal, resultando numa vazão superior à esperada, mascarando o valor de Cd. Já os bocais com diâmetro superior a5,4 mm não apresentaram tais vazamentos, sendo registrados valores de coeficiente de descarga na faixa tradicional de bocais (0,92 – 0,98).
UNITERMOS: dimensionamento hidráulico, uniformidade, bocais
TEIXEIRA, M. B.; MELO, R. F. de; COELHO, R. D. DISCHARGE COEFFICIENTS OF CENTER PIVOT EMITTERS
2 ABSTRACT
Aiming to evaluate the discharge coefficient of different diameters of center pivot emitters, 35 nozzles of different diameters (three replications, totalizing 105 nozzles) were analyzed. A digital manometer and an inductive magnetic meter were used to measure hydraulic pressure (kPa) and flow rate (m3 h-1). Treated water at a 25ºC temperature was used in the experiment. The results showed that some discharge coefficient values were higher than 1.0 for small diameters (from 2.0 to5.4 mm), showing that a pressure increase caused a leak resulting in high flow values when compared to theoretical orifice equation (discharge coefficient). Nozzle diameters that were up to5.4 mm did not present leaking problems related to pressure increase, recording traditional values for discharge coefficient: 0.92 – 0.98.
KEYWORDS: hydraulic design, uniformity, nozzle
Downloads
Published
How to Cite
Issue
Section
License
This magazine provides public access to all its content, following the principle that free access to research generates greater global knowledge exchange. Such access is associated with a growing reading and citation of an author's work. The copyright of articles published in Revista Irriga is the property of the authors, with first publication rights for the journal. Because they appear in this publicly accessible magazine, articles are free to use, for their own purposes, for educational and non-commercial purposes. Further details can be obtained at http://creativecommons.org/licenses/by-nc-nd/4.0