ALTERAÇÕES EM VARIÁVEIS AGROMETEOROLÓGICAS PELO USO DE ESTUFA PLÁSTICA
DOI:
https://doi.org/10.15809/irriga.2002v7n2p130-141Abstract
ALTERAÇÕES EM VARIÁVEIS AGROMETEOROLÓGICAS PELO USO DE ESTUFA PLÁSTICA
Reginaldo Ferreira Santos
Marcio Antonio Vilas BoasCentro de Ciências Exatas e Tecnológicas,Universidade Estadual do Oeste do Paraná, CP 711,
CEP 858114-110, Cascavel – PR, Fone: (0xx45) 220-3155, E-mail: rfsantos@unioeste.br
Antonio Evaldo KlarDepartamento de Engenharia Rural, Faculdade de Ciências Agronômicas, Universidade Estadual Paulista, CP 237, CEP 18603-970, Botucatu - SP, E-mail: klar@fca.unesp.br - Pesquisador Científico do CNPq
1 RESUMO
O presente trabalho teve como objetivo verificar o efeito da cobertura plástica de polietileno de baixa densidade (PEBD) sobre a temperatura do ar, umidade relativa do ar, déficit de saturação e tensão de vapor d'água no ar. Pelos resultados encontrados neste trabalho as médias mensais de temperatura do ar no interior da estufa plástica foram superiores em 7,5%, a umidade relativa do ar em 7%, o déficit de saturação em 34% e a tensão atual de vapor d'água no ar em 4,7%, em relação aos valores determinados à campo. Observou-se maior efeito da cobertura plástica sobre as temperaturas máximas, as quais levaram as médias mensais a ficar entre 3,8 a 7,8 oC acima dos valores médios determinados no campo. Os valores médios mensais mínimos de temperatura e umidade relativa do ar entre a estufa e o campo apresentaram menor amplitude de variação que os valores máximos.
UNITERMOS: estufa plástica, temperatura do ar, umidade relativa do ar.
SANTOS, R.F., VILAS BOAS, M.A., KLAR, A.E. Agrometeorological parameter changes in a plastic GREENHOUSE
2 ABSTRACT
The aim of this study was to verify the influence of the plastic greenhouse set up in a north-south main axis orientation on several meteorological parameters in relation to those from outside conditions. The results obtained from this study showed that the means of monthly air temperature were 7.5%; relative humidity, 7.0%; saturation deficit, 34%; and actual water vapour pressure, 4.75% higher inside the greenhouse than outside it. The maximum air temperature means were 3.8 to 7.8 0C higher inside the greenhouse than outside it. The minimum air temperature and relative humidity means showed lower range of variation in both environments compared to the one from the maximum values of the same parameters.
KEYWORDS: air temperature, air relative humidity and vapor pressure
Downloads
Published
How to Cite
Issue
Section
License
This magazine provides public access to all its content, following the principle that free access to research generates greater global knowledge exchange. Such access is associated with a growing reading and citation of an author's work. The copyright of articles published in Revista Irriga is the property of the authors, with first publication rights for the journal. Because they appear in this publicly accessible magazine, articles are free to use, for their own purposes, for educational and non-commercial purposes. Further details can be obtained at http://creativecommons.org/licenses/by-nc-nd/4.0