AJUSTE DA EQUAÇÃO DE HAZEN-WILLIANS PARA DETERMINAÇÃO DA PERDA DE CARGA CONTÍNUA EM TUBULAÇÕES DE PVC
DOI:
https://doi.org/10.15809/irriga.2019v1n1p94-100Resumo
AJUSTE DA EQUAÇÃO DE HAZEN-WILLIANS PARA DETERMINAÇÃO DA PERDA DE CARGA CONTÍNUA EM TUBULAÇÕES DE PVC
EUGENIO PACELI MIRANDA1; TATIANA BELO DE SOUSA CUSTODIO2; FRANCISCO UCHOA DE LIMA3; TAIANE ALMENDA PEREIRA4 E ANDRE LUIZ RIBEIRO BICUDO5
1Professor, Doutor IFCE, Campus Iguatu/CE, Rua Plácido Almino Uchoa, 60, Iguatu/Ceará. CEP: 63.500-000, Brasil, email:paceli.miranda@gmail.com;
2 Tecnólogo em Irrigação e Drenagem, IFCE, Campus Iguatu, Rodovia Iguatu-Várzea Alegre km 05, CEP: 63.500-000, Brasil, email: tathyannabello@gmail.com;
3Graduando em Tecnologia em Irrigação e Drenagem, IFCE, Campus Iguatu, Rodovia Iguatu-Várzea Alegre km 05, CEP: 63.500-000, Brasil, e-mail: uchoafco33@gmail.com;
4Graduandos em Tecnologia em Irrigação e Drenagem, IFCE, Campus Iguatu, Rodovia Iguatu-Várzea Alegre km 05, CEP: 63.500-000, Brasil, e-mail: taianeirrigacoa@gmail.com;
5 Prof. do Colégio Técnico Industrial "Prof. Isaac Portal Roldan", Unesp, Campus Bauru. Av. Eng. Luis Edmundo Carrijo Coube, 14-01, CEP: 17.033-360, Brasil, e-mail: andre.bicudo@unesp.br
1 RESUMO
A perda de carga é um parâmetro fundamental para o dimensionamento das tubulações, estando diretamente relacionada ao custo dessas tubulações, a seleção do sistema de bombeamento e o custo com o consumo de energia elétrica. Nesse estudo ajustou-se a equação de Hazen-Willians e comparou com a equação de Darcy-Weisbach. O desempenho da equação ajustada foi determinada pelo índice de concordância (c), Erro Padrão Estatístico (EPE) e o Erro Absoluto Médio (EAM). Os resultados mostram que todos os índices usados para verificar o desempenho da equação de Hazen-Willians ajustada melhoraram. A maior diferença entre os valores da perda de carga contínua entre o método de Darcy-Weisbach e a equação de Hazen-Willians ajustada ficou em torno de 0,08%, valor que pode ser considerado extremamente baixo.
Palavras-chave: Perda de carga, Darcy- Weisbach, diâmetro.
MIRANDA, E. P; CUSTODIO, T. B. S; LIMA, F. U; PEREIRA, T. A.; BICUDO, A. L. R.
ADJUSTMENT OF THE HAZEN-WILLIANS EQUATION FOR DETERMINATION OF CONTINUOUS PRESSURE DROP IN PVC PIPE
2 ABSTRACT
The head loss is a fundamental parameter for the dimensioning of the pipes, being directly related to the cost of these pipes, the selection of the pumping system and the energy cost of electricity. That study fitted the Hazen-Williams equation and compared it with the Darcy-Weisbach equation. The performance of the adjusted equation was determined by the concordance index (c), Statistical Standard Error (EPE) and Mean Absolute Error (EAM). The results show that all gridded indices to verify the performance of the adjusted Hazen-Willians equation have improved. The largest difference between the values of continuous load loss between the Darcy-Weisbach method and the adjusted Hazen-Williams equation was about 0.08%, which can be considered extremely low
Keywords: Head loss, Darcy-Weisbach, diameter.
Downloads
Publicado
Como Citar
Edição
Seção
Licença
Esta revista proporciona acesso público a todo seu conteúdo, seguindo o princípio que tornar gratuito o acesso a pesquisas gera um maior intercâmbio global de conhecimento. Tal acesso está associado a um crescimento da leitura e citação do trabalho de um autor. Os direitos autorais dos artigos publicados na Revista Irriga são de propriedade dos autores, com direitos de primeira publicação para o periódico. Em virtude de aparecerem nesta revista de acesso público, os artigos são de uso gratuito, com atribuições próprias, para fins educacionais e não-comerciais. Maiores detalhes podem ser obtidos em http://creativecommons.org/licenses/by-nc-nd/4.0