TRATAMENTO PARA DESENTUPIMENTO DE GOTEJADORES CONVENCIONAIS
DOI:
https://doi.org/10.15809/irriga.2008v13n2p235-248Resumo
TRATAMENTO PARA DESENTUPIMENTO DE GOTEJADORES CONVENCIONAIS
Marconi Batista Teixeira; Ralini Ferreira de Melo; Rubens Duarte Coelho; Osvaldo Rettore Neto; Pablo Atahualpa de Aguiar Ribeiro
Departamento de Engenharia Rural, Escola Superior de Agricultura Luiz de Queiroz, Universidade de São Paulo, Piracicaba, SP, marconi@esalq.usp.br
1 RESUMO
Este trabalho teve como objetivo verificar a recuperação de emissores convencionais que apresentavam, em campo, problemas de entupimento causados por problemas biológico ou químico. O experimento foi realizado em uma Bancadade ensaios instalada no Laboratório de Irrigação do DER – ESALQ – USP, utilizando-se os seguintes tratamentos químicos da água para recuperação dos emissores: a) 10 mg L-1 de cloro livre; b) 50 mg L-1 de cloro livre; e c) ácido nítrico a pH 2,0. A fonte de cloro utilizada foi hipoclorito de sódio (10%), sendo que o pH foi mantido na faixa de 5,5 a 6,0 para maior ação do ácido hipocloroso. A aplicação das dosagens foi feita durante 2 horas, deixando as linhas gotejadoras descansarem expostas à ação dos tratamentos por 24 horas, quando, então, realizava-se a leitura de vazão. O delineamento experimental adotado foi o DIC em esquema fatorial 5x3, sendo utilizados os testes “F” para análise de variância e Tuckey a 5% de significância para comparação de médias. O tratamento com 50 mg L -1 de cloro livre foi o mais eficiente estatisticamente a 5% de significância pelo teste de Tukey para recuperação da vazão dos gotejadores a valores próximos da vazão nominal de catálogo.
UNITERMOS: irrigação localizada, tratamento químico, uniformidade de distribuição de água.
TEIXEIRA, M. B.; MELO, R. F. de; COELHO, R. D.; RETTORE NETO, O.; RIBEIRO, P. A. de A. TREATMENT FOR CLOGGED EMITTERS
2 ABSTRACT
This work aimed to verify the recovery of conventional emitters that presented blockage problems in the field caused by biological or chemical problems. The experiment was performed in a trial counter installed in the Irrigation Laboratory at ESALQ-USP, using the following chemical water treatments for clogged emitters: a) 10 mg Lˉ¹ of free chlorine,
b) 50 mgLˉ¹ of free chlorine, and c) nitric acid at 2.0 pH. The used chlorine source was sodium hypochlorite (10%) and pH was kept from 5.5 to 6.0. The application was done for 2 hours, then the line emitters rested and exposed to the action of the treatments for 24 hours, when then the flow reading was made. The adopted experimental outline was DIC in a 5x3 factorial scheme, using Tests “F” for variance analysis and Tukey’s at 5% to compare averages. The treatment to recover emitter discharge to its original value was statistically more efficient according to Tukey’s test at 5%, when 50 mgLˉ¹ of free chlorine was applied.
KEY WORDS: trickle irrigation, chemical treatment, uniformity of dripper discharge
Downloads
Publicado
Como Citar
Edição
Seção
Licença
Esta revista proporciona acesso público a todo seu conteúdo, seguindo o princípio que tornar gratuito o acesso a pesquisas gera um maior intercâmbio global de conhecimento. Tal acesso está associado a um crescimento da leitura e citação do trabalho de um autor. Os direitos autorais dos artigos publicados na Revista Irriga são de propriedade dos autores, com direitos de primeira publicação para o periódico. Em virtude de aparecerem nesta revista de acesso público, os artigos são de uso gratuito, com atribuições próprias, para fins educacionais e não-comerciais. Maiores detalhes podem ser obtidos em http://creativecommons.org/licenses/by-nc-nd/4.0