DESENVOLVIMENTO E AVALIAÇÃO DE DISPOSITIVOS DE CONTROLE DE VAZÃO DERIVADA EM CANAIS DE IRRIGAÇÃO

Autores

  • Camilo de Lelis de Andrade Unesp-FCA-Botucatu-SP
  • Bruno Leite Teixeira Perroni
  • Paulo Emílio Pereira de Albuquerque
  • Gabriel Roberto Oliveira
  • Fernando Falco Pruski
  • Flávio Aparecido Gonçalves

DOI:

https://doi.org/10.15809/irriga.2007v12n4p439-455

Resumo

DESENVOLVIMENTO E AVALIAÇÃO DE DISPOSITIVOS DE CONTROLE DE VAZÃO DERIVADA EM CANAIS DE IRRIGAÇÃO

 

 

Camilo de Lelis Teixeira de Andrade1; Bruno Leite Teixeira Perroni2; Paulo Emílio Pereira de Albuquerque1; Gabriel Roberto Oliveira1; Fernando Falco Pruski3; Flávio Aparecido Gonçalves3

1Embrapa Milho e Sorgo,  Sete Lagoas, MG,  camilo@cnpms.embrapa.br

2Departamento de Engenharia, Universidade Federal de Lavras, Lavras, MG

3Departamento de Engenharia Agrícola, Universidade Federal de Viçosa, Viçosa, MG

 

 

1 RESUMO

 

Em comportas que operam como orifícios retangulares, a variação do nível da água no canal afeta a vazão do orifício, o que provoca erros na estimativa do volume de água derivada. Objetivou-se com esse projeto desenvolver e avaliar dispositivos que possibilitem melhor controle da derivação de água para os lotes. A comporta tipo Módulo de Máscara XX1, comumente utilizada no perímetro,foi aferida no local e suas características hidráulicas comparadas com os dados do fabricante. Três tipos de dispositivos de derivação de água foram desenvolvidos e avaliados, todos baseados na manutenção do nível da água sobre um orifício. No protótipo 1, procura-se manter o nível da água fechando ou abrindo uma portinhola que atua contra o fluxo de entrada de água. No protótipo 2, uma portinhola atua no sentido do fluxo de água como em um carneiro hidráulico. No protótipo 3 o nível da água é mantido constante fechando ou abrindo a saída de um mangote flexível. O módulo de 10 Ls-1 da comporta XX1 apresentou erros de até 20% da vazão nominal quando submetida a níveis de água no canal acima ou abaixo do valor recomendado, conforme reportado no catálogo do fabricante. Dos três protótipos desenvolvidos, o que proporcionou melhor resultado foi de número 3. Testes com o protótipo 3 indicaram que variações máximas de 3,4% na vazão derivada foram observadas para oscilações de30 cm no nível do canal.

 

UNITERMOS: comporta, orifício, medição de água.

 

 

ANDRADE, C. L. T.; PERRONI, B. L. T.; ALBUQUERQUE, P. E. P.; PRUSKI, F. F.; OLIVEIRA, G. R. DEVELOPMENT AND EVALUATION OF IRRIGATION CANAL DEVICES FOR WATER TURNOUT CONTROL

 

 

2 ABSTRACT

 

In water turnouts that operate by gravity as a rectangular gate, variation on the canal water level affects the estimated discharge to plots. This work objective was to develop and evaluate devices for a better water turnout to plots. An existing commercial gate model XX1, was evaluated in situ and its hydraulic characteristics compared to manufacturer´s data. Three types of water turnout devices were developed and evaluated, all of them based on the principle of maintaining a constant water level over an orifice. In prototype 1, water level is maintained by opening or closing a gate against the inlet water flow. In prototype 2, the gate is positioned in the flow direction, like in a water hammer. In prototype 3, water level is kept by opening or closing a flat hose outlet. The 10 Ls-1 module of a XX1 gate causes errors of up to 20% of the nominal discharge when operated under water levels above or below the recommended value by the manufacturer. Considering three developed prototypes, a better water turnout control was obtained with prototype 3. Tests with prototype 3 indicated that a maximum of 3.4% of the derived discharged was observed for fluctuations of up to30 cm on the canal level. 

 

KEYWORDS: gate, orifice, water measurement.

Downloads

Publicado

2007-12-06

Como Citar

ANDRADE, Camilo de Lelis de; PERRONI, Bruno Leite Teixeira; ALBUQUERQUE, Paulo Emílio Pereira de; OLIVEIRA, Gabriel Roberto; PRUSKI, Fernando Falco; GONÇALVES, Flávio Aparecido. DESENVOLVIMENTO E AVALIAÇÃO DE DISPOSITIVOS DE CONTROLE DE VAZÃO DERIVADA EM CANAIS DE IRRIGAÇÃO. IRRIGA, [S. l.], v. 12, n. 4, p. 439–455, 2007. DOI: 10.15809/irriga.2007v12n4p439-455. Disponível em: http://revistas.fca.unesp.br/index.php/irriga/article/view/3329. Acesso em: 20 nov. 2024.